Evaluating bias reduction methods in binary Emax model for reliable dose-response estimation

Jiangshan Zhang et al.

Journal of Biopharmaceutical Statistics2026https://doi.org/10.1080/10543406.2026.2627387article
ABDC C
Weight
0.50

What the paper says

The Binary Emax model is widely employed in dose-response analysis during Phase II clinical studies to identify the optimal dose for subsequence confirmatory trials. The parameter estimation and inference heavily rely on the asymptotic properties of Maximum Likelihood (ML) estimators; however, this approach may be questionable under small or moderate sample sizes and is not robust to violations of model assumptions. To provide a reliable solution, this paper examines three bias-reduction methods: the Cox-Snell bias correction, Firth's score modification, and a maximum penalized likelihood estimator (MPLE) using Jeffreys prior. Through comprehensive simulation studies, we evaluate the performance of these methods in reducing bias and controlling variance, especially when model assumptions are violated. The results demonstrate that both Firth's and MPLE methods provide robust estimates, with MPLE outperforming in terms of stability and lower variance. We further illustrate the practical application of these methods using data from the TURANDOT study, a Phase II clinical trial. Our findings suggest that MPLE with Jeffreys prior offers an effective and reliable alternative to Firth's method, particularly for dose-response relationships that deviate from monotonicity, making it valuable for robust parameter estimation in dose-ranging studies.

Open paper page →

Cite this paper

https://doi.org/https://doi.org/10.1080/10543406.2026.2627387

Or copy a formatted citation

@article{jiangshan2026,
  title        = {{Evaluating bias reduction methods in binary Emax model for reliable dose-response estimation}},
  author       = {Jiangshan Zhang et al.},
  journal      = {Journal of Biopharmaceutical Statistics},
  year         = {2026},
  doi          = {https://doi.org/https://doi.org/10.1080/10543406.2026.2627387},
}

Paste directly into BibTeX, Zotero, or your reference manager.

Flag this paper

Evaluating bias reduction methods in binary Emax model for reliable dose-response estimation

Flags are reviewed by the Arbiter methodology team within 5 business days.


Evidence weight

0.50

Balanced mode · F 0.40 / M 0.15 / V 0.05 / R 0.40

F · citation impact0.50 × 0.4 = 0.20
M · momentum0.50 × 0.15 = 0.07
V · venue signal0.50 × 0.05 = 0.03
R · text relevance †0.50 × 0.4 = 0.20

† Text relevance is estimated at 0.50 on the detail page — for your query’s actual relevance score, open this paper from a search result.