Abstract

Computed tomography (CT) has been a powerful diagnostic tool since its emergence in the 1970s. Using CT data, 3D structures of human internal organs and tissues, such as blood vessels, can be reconstructed using professional software. This 3D reconstruction is crucial for surgical operations and can serve as a vivid medical teaching example. However, traditional 3D reconstruction heavily relies on manual operations, which are time-consuming, subjective, and require substantial experience. To address this problem, we develop a novel semiparametric Gaussian mixture model tailored for the 3D reconstruction of blood vessels. This model extends the classical Gaussian mixture model by enabling nonparametric variations in the component-wise parameters of interest according to voxel positions. We develop a kernel-based expectation-maximization algorithm for estimating the model parameters, accompanied by a supporting asymptotic theory. Furthermore, we propose a novel regression method for optimal bandwidth selection. Compared to the conventional cross-validation-based (CV) method, the regression method outperforms the CV method in terms of computational and statistical efficiency. In application, this methodology facilitates the fully automated reconstruction of 3D blood vessel structures with remarkable accuracy.

4 citations

Open via your library →

Cite this paper

https://doi.org/https://doi.org/10.1093/biostatistics/kxae013

Or copy a formatted citation

@article{qianhan2024,
  title        = {{A semiparametric Gaussian mixture model for chest CT-based 3D blood vessel reconstruction}},
  author       = {Qianhan Zeng et al.},
  journal      = {Biostatistics},
  year         = {2024},
  doi          = {https://doi.org/https://doi.org/10.1093/biostatistics/kxae013},
}

Paste directly into BibTeX, Zotero, or your reference manager.

Flag this paper

A semiparametric Gaussian mixture model for chest CT-based 3D blood vessel reconstruction

Flags are reviewed by the Arbiter methodology team within 5 business days.


Evidence weight

0.46

Balanced mode · F 0.40 / M 0.15 / V 0.05 / R 0.40

F · citation impact0.36 × 0.4 = 0.14
M · momentum0.60 × 0.15 = 0.09
V · venue signal0.50 × 0.05 = 0.03
R · text relevance †0.50 × 0.4 = 0.20

† Text relevance is estimated at 0.50 on the detail page — for your query’s actual relevance score, open this paper from a search result.