Experiment and Numerical Investigation into the Direct Shear Performance of Bridge Column Joints Connected by Grouted Sleeves

Xiaopeng Li et al.

Transportation Research Record2026https://doi.org/10.1177/03611981261425978article
ABDC B
Weight
0.50

What the paper says

Grouted sleeves are extensively utilized in precast columns within the framework of accelerated bridge construction, with their components typically joined by splice joints. Experiment and numerical methods were adopted to investigate the shear performance of these splice joints connected by grouted sleeves. A series of three direct shear tests was conducted on sleeve connections under monotonic loading conditions. Furthermore, post-test analysis involved sectioning the specimens along the interface to examine the connection’s internal structure. The experiment findings confirmed that the shear strength was derived from a combination of cohesion, dowel action, and friction. Cohesion was observed to dissipate at the onset of displacement, after which the shear force increased progressively with lateral displacement. Additionally, the primary mode of connection damage was identified as the crushing of grout and the adjacent concrete around the steel reinforcement. Subsequently, finite element (FE) models were developed and validated against the direct shear tests with regard to failure modes and load-slip relationships. Utilizing these FE models, a parametric study was carried out to identify the key factors influencing the shear strength of the splice joints.

Open paper page →

Cite this paper

https://doi.org/https://doi.org/10.1177/03611981261425978

Or copy a formatted citation

@article{xiaopeng2026,
  title        = {{Experiment and Numerical Investigation into the Direct Shear Performance of Bridge Column Joints Connected by Grouted Sleeves}},
  author       = {Xiaopeng Li et al.},
  journal      = {Transportation Research Record},
  year         = {2026},
  doi          = {https://doi.org/https://doi.org/10.1177/03611981261425978},
}

Paste directly into BibTeX, Zotero, or your reference manager.

Flag this paper

Experiment and Numerical Investigation into the Direct Shear Performance of Bridge Column Joints Connected by Grouted Sleeves

Flags are reviewed by the Arbiter methodology team within 5 business days.


Evidence weight

0.50

Balanced mode · F 0.40 / M 0.15 / V 0.05 / R 0.40

F · citation impact0.50 × 0.4 = 0.20
M · momentum0.50 × 0.15 = 0.07
V · venue signal0.50 × 0.05 = 0.03
R · text relevance †0.50 × 0.4 = 0.20

† Text relevance is estimated at 0.50 on the detail page — for your query’s actual relevance score, open this paper from a search result.